From: Bugzilla Bug 5351
"After resuming from S3 (suspended while in X), the LCD panel stays black .
However, the laptop is up again, and I can SSH into it from another
machine.
I can get the panel working again, when I first direct video output to the
CRT output of the laptop, and then back to LCD (done by repeatedly hitting
Fn+F5 buttons on the Toshiba, which directs output to either LCD, CRT or
TV) None of this ever happened with older kernels."
This bug is due to the recently added vesafb_blank() method in vesafb. It
works with CRT displays, but has a high incidence of problems in laptop
users. Since CRT users don't really get that much benefit from hardware
blanking, drop support for this.
Signed-off-by: Antonino Daplas <adaplas@pol.net>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
diff --git a/include/linux/screen_info.h b/include/linux/screen_info.h
index 76850b7..6336987 100644
--- a/include/linux/screen_info.h
+++ b/include/linux/screen_info.h
@@ -41,8 +41,7 @@
u16 vesapm_off; /* 0x30 */
u16 pages; /* 0x32 */
u16 vesa_attributes; /* 0x34 */
- u32 capabilities; /* 0x36 */
- /* 0x3a -- 0x3f reserved for future expansion */
+ /* 0x36 -- 0x3f reserved for future expansion */
};
extern struct screen_info screen_info;