msm: 8960/8064: robust battery detection
To ensure proper battery id dectection on LiQUID and MTP
use machine_is_msm8960/8064_mtp/cdp to determine which
calibration data to use for battery. If platform is
unknown fall back on regular battery id detection.
Change-Id: I2f5629572d1e5fcac0a2feb114947b91a96f3bf0
Signed-off-by: David Keitel <dkeitel@codeaurora.org>
diff --git a/arch/arm/mach-msm/board-8064-pmic.c b/arch/arm/mach-msm/board-8064-pmic.c
index 364df81..bd5f703 100644
--- a/arch/arm/mach-msm/board-8064-pmic.c
+++ b/arch/arm/mach-msm/board-8064-pmic.c
@@ -356,6 +356,7 @@
static struct pm8921_bms_platform_data
apq8064_pm8921_bms_pdata __devinitdata = {
+ .battery_type = BATT_UNKNOWN,
.r_sense = 10,
.i_test = 2500,
.v_failure = 3000,
@@ -428,5 +429,9 @@
if (machine_is_apq8064_rumi3()) {
apq8064_pm8921_irq_pdata.devirq = 0;
apq8064_pm8821_irq_pdata.devirq = 0;
+ } else if (machine_is_apq8064_mtp()) {
+ apq8064_pm8921_bms_pdata.battery_type = BATT_PALLADIUM;
+ } else if (machine_is_apq8064_liquid()) {
+ apq8064_pm8921_bms_pdata.battery_type = BATT_DESAY;
}
}