hvc_console: rework setup to replace irq functions with callbacks

This patch tries to change hvc_console to not use request_irq/free_irq if
the backend does not use irqs. This allows virtio_console to use hvc_console
without having a linker reference to request_irq/free_irq.

In addition, together with patch 2/3 it improves the performance for virtio
console input. (an earlier version of this patch was tested by Yajin on lguest)

The irq specific code is moved to hvc_irq.c and selected by the drivers that
use irqs (System p, System i, XEN).

I replaced "int irq" with the opaque "int data". The request_irq and
free_irq calls are replaced with notifier_add and notifier_del. I have also
changed the code a bit to call the notifier_add and notifier_del inside the
spinlock area as the callbacks are found via hp->ops.

Changes since last version:
o remove ifdef
o reintroduce "irq_requested" as "notified"
o cleanups, sparse..

I did not move the timer based polling into a separate polling scheme. I
played with several variants, but it seems we need to sleep/schedule in
a thread even for irq based consoles, as there are throttleing and buffer
size constraints.

I also kept hvc_struct defined in hvc_console.h so that hvc_irq.c can access
the irq_requested element.

Feedback is appreciated. virtio_console is currently the only available console
for kvm on s390. I plan to push this change as soon as all affected parties
agree on it. I would love to get test results from System p, Xen etc.

Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
Signed-off-by: Rusty Russell <rusty@rustcorp.com.au>
diff --git a/drivers/char/Kconfig b/drivers/char/Kconfig
index 67b0757..d825361 100644
--- a/drivers/char/Kconfig
+++ b/drivers/char/Kconfig
@@ -578,11 +578,14 @@
 	  It will automatically be selected if one of the back-end console drivers
 	  is selected.
 
+config HVC_IRQ
+	bool
 
 config HVC_CONSOLE
 	bool "pSeries Hypervisor Virtual Console support"
 	depends on PPC_PSERIES
 	select HVC_DRIVER
+	select HVC_IRQ
 	help
 	  pSeries machines when partitioned support a hypervisor virtual
 	  console. This driver allows each pSeries partition to have a console
@@ -593,6 +596,7 @@
 	depends on PPC_ISERIES
 	default y
 	select HVC_DRIVER
+	select HVC_IRQ
 	help
 	  iSeries machines support a hypervisor virtual console.
 
@@ -614,6 +618,7 @@
 	bool "Xen Hypervisor Console support"
 	depends on XEN
 	select HVC_DRIVER
+	select HVC_IRQ
 	default y
 	help
 	  Xen virtual console device driver