  "commit": "75d8807962fc7529b4946e9ec92cae197be5a967",
  "tree": "9e5370ea7e1c727a18c4cb47c8403779456cbebe",
  "parents": [
    "8e552c36d90c03d2cabf5373788998966751b609"
  ],
  "author": {
    "name": "Andres Salomon",
    "email": "dilinger@queued.net",
    "time": "Wed May 14 16:20:38 2008 -0700"
  },
  "committer": {
    "name": "Anton Vorontsov",
    "email": "cbouatmailru@gmail.com",
    "time": "Mon May 19 01:44:36 2008 +0400"
  },
  "message": "power_supply: fix up CHARGE_COUNTER output to be more precise\n\nAs Richard Smith pointed out, ACR * 6250 / 15 provides for less\nprecision loss than ACR * 4167 / 10, _and_ it doesn\u0027t overflow.  Switch\nto using that equation for CHARGE_COUNTER.\n\nSigned-off-by: Andres Salomon \u003cdilinger@debian.org\u003e\nCc: \"Richard A. Smith\" \u003crichard@laptop.org\u003e\nSigned-off-by: Andrew Morton \u003cakpm@linux-foundation.org\u003e\nSigned-off-by: Anton Vorontsov \u003ccbouatmailru@gmail.com\u003e\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "9dd1589733c2270bfcae12e8f3f82e894165d04a",
      "old_mode": 33188,
      "old_path": "drivers/power/olpc_battery.c",
      "new_id": "32570af3c5c904fa86cffe26efbcc7650757d474",
      "new_mode": 33188,
      "new_path": "drivers/power/olpc_battery.c"
    }
  ]
}