|  | Kernel driver adm1275 | 
|  | ===================== | 
|  |  | 
|  | Supported chips: | 
|  | * Analog Devices ADM1275 | 
|  | Prefix: 'adm1275' | 
|  | Addresses scanned: - | 
|  | Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1275.pdf | 
|  |  | 
|  | Author: Guenter Roeck <guenter.roeck@ericsson.com> | 
|  |  | 
|  |  | 
|  | Description | 
|  | ----------- | 
|  |  | 
|  | This driver supports hardware montoring for Analog Devices ADM1275 Hot-Swap | 
|  | Controller and Digital Power Monitor. | 
|  |  | 
|  | The ADM1275 is a hot-swap controller that allows a circuit board to be removed | 
|  | from or inserted into a live backplane. It also features current and voltage | 
|  | readback via an integrated 12-bit analog-to-digital converter (ADC), accessed | 
|  | using a PMBus. interface. | 
|  |  | 
|  | The driver is a client driver to the core PMBus driver. Please see | 
|  | Documentation/hwmon/pmbus for details on PMBus client drivers. | 
|  |  | 
|  |  | 
|  | Usage Notes | 
|  | ----------- | 
|  |  | 
|  | This driver does not auto-detect devices. You will have to instantiate the | 
|  | devices explicitly. Please see Documentation/i2c/instantiating-devices for | 
|  | details. | 
|  |  | 
|  |  | 
|  | Platform data support | 
|  | --------------------- | 
|  |  | 
|  | The driver supports standard PMBus driver platform data. Please see | 
|  | Documentation/hwmon/pmbus for details. | 
|  |  | 
|  |  | 
|  | Sysfs entries | 
|  | ------------- | 
|  |  | 
|  | The following attributes are supported. Limits are read-write; all other | 
|  | attributes are read-only. | 
|  |  | 
|  | in1_label		"vin1" or "vout1" depending on chip variant and | 
|  | configuration. | 
|  | in1_input		Measured voltage. From READ_VOUT register. | 
|  | in1_min			Minumum Voltage. From VOUT_UV_WARN_LIMIT register. | 
|  | in1_max			Maximum voltage. From VOUT_OV_WARN_LIMIT register. | 
|  | in1_min_alarm		Voltage low alarm. From VOLTAGE_UV_WARNING status. | 
|  | in1_max_alarm		Voltage high alarm. From VOLTAGE_OV_WARNING status. | 
|  |  | 
|  | curr1_label		"iout1" | 
|  | curr1_input		Measured current. From READ_IOUT register. | 
|  | curr1_max		Maximum current. From IOUT_OC_WARN_LIMIT register. | 
|  | curr1_max_alarm		Current high alarm. From IOUT_OC_WARN_LIMIT register. |