usb: gadget: android: always update the sw_connected state

If we go through connected->configured->disconnected cycle very quickly,
it is possible that we may not generate a disconnect uevent to userspace.
Connected+configured could have happened before the work item got
executed, and thus would not have updated the sw_connected state. On
the disconnect, it would have noticed that a config is no longer there
but since sw_connected was still 0, it would not have sent the
disconnect event.

Change-Id: Id71175f784e3e1cf3f828bd8b24fceea1078a06b
Signed-off-by: Dima Zavin <dima@android.com>
diff --git a/drivers/usb/gadget/android.c b/drivers/usb/gadget/android.c
index 8ff9972..d109bfb 100644
--- a/drivers/usb/gadget/android.c
+++ b/drivers/usb/gadget/android.c
@@ -167,12 +167,11 @@
 	unsigned long flags;
 
 	spin_lock_irqsave(&cdev->lock, flags);
-        if (cdev->config) {
+        if (cdev->config)
 		uevent_envp = configured;
-	} else if (dev->connected != dev->sw_connected) {
-		dev->sw_connected = dev->connected;
-		uevent_envp = dev->sw_connected ? connected : disconnected;
-	}
+	else if (dev->connected != dev->sw_connected)
+		uevent_envp = dev->connected ? connected : disconnected;
+	dev->sw_connected = dev->connected;
 	spin_unlock_irqrestore(&cdev->lock, flags);
 
 	if (uevent_envp) {