|  | /* | 
|  | * Copyright (C) 2011 Samsung Electronics Co., Ltd. | 
|  | * MyungJoo Ham <myungjoo.ham@samsung.com> | 
|  | * | 
|  | * This driver enables to monitor battery health and control charger | 
|  | * during suspend-to-mem. | 
|  | * Charger manager depends on other devices. register this later than | 
|  | * the depending devices. | 
|  | * | 
|  | * This program is free software; you can redistribute it and/or modify | 
|  | * it under the terms of the GNU General Public License version 2 as | 
|  | * published by the Free Software Foundation. | 
|  | **/ | 
|  |  | 
|  | #include <linux/io.h> | 
|  | #include <linux/module.h> | 
|  | #include <linux/irq.h> | 
|  | #include <linux/interrupt.h> | 
|  | #include <linux/rtc.h> | 
|  | #include <linux/slab.h> | 
|  | #include <linux/workqueue.h> | 
|  | #include <linux/platform_device.h> | 
|  | #include <linux/power/charger-manager.h> | 
|  | #include <linux/regulator/consumer.h> | 
|  |  | 
|  | /* | 
|  | * Regard CM_JIFFIES_SMALL jiffies is small enough to ignore for | 
|  | * delayed works so that we can run delayed works with CM_JIFFIES_SMALL | 
|  | * without any delays. | 
|  | */ | 
|  | #define	CM_JIFFIES_SMALL	(2) | 
|  |  | 
|  | /* If y is valid (> 0) and smaller than x, do x = y */ | 
|  | #define CM_MIN_VALID(x, y)	x = (((y > 0) && ((x) > (y))) ? (y) : (x)) | 
|  |  | 
|  | /* | 
|  | * Regard CM_RTC_SMALL (sec) is small enough to ignore error in invoking | 
|  | * rtc alarm. It should be 2 or larger | 
|  | */ | 
|  | #define CM_RTC_SMALL		(2) | 
|  |  | 
|  | #define UEVENT_BUF_SIZE		32 | 
|  |  | 
|  | static LIST_HEAD(cm_list); | 
|  | static DEFINE_MUTEX(cm_list_mtx); | 
|  |  | 
|  | /* About in-suspend (suspend-again) monitoring */ | 
|  | static struct rtc_device *rtc_dev; | 
|  | /* | 
|  | * Backup RTC alarm | 
|  | * Save the wakeup alarm before entering suspend-to-RAM | 
|  | */ | 
|  | static struct rtc_wkalrm rtc_wkalarm_save; | 
|  | /* Backup RTC alarm time in terms of seconds since 01-01-1970 00:00:00 */ | 
|  | static unsigned long rtc_wkalarm_save_time; | 
|  | static bool cm_suspended; | 
|  | static bool cm_rtc_set; | 
|  | static unsigned long cm_suspend_duration_ms; | 
|  |  | 
|  | /* Global charger-manager description */ | 
|  | static struct charger_global_desc *g_desc; /* init with setup_charger_manager */ | 
|  |  | 
|  | /** | 
|  | * is_batt_present - See if the battery presents in place. | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | */ | 
|  | static bool is_batt_present(struct charger_manager *cm) | 
|  | { | 
|  | union power_supply_propval val; | 
|  | bool present = false; | 
|  | int i, ret; | 
|  |  | 
|  | switch (cm->desc->battery_present) { | 
|  | case CM_FUEL_GAUGE: | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_PRESENT, &val); | 
|  | if (ret == 0 && val.intval) | 
|  | present = true; | 
|  | break; | 
|  | case CM_CHARGER_STAT: | 
|  | for (i = 0; cm->charger_stat[i]; i++) { | 
|  | ret = cm->charger_stat[i]->get_property( | 
|  | cm->charger_stat[i], | 
|  | POWER_SUPPLY_PROP_PRESENT, &val); | 
|  | if (ret == 0 && val.intval) { | 
|  | present = true; | 
|  | break; | 
|  | } | 
|  | } | 
|  | break; | 
|  | } | 
|  |  | 
|  | return present; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * is_ext_pwr_online - See if an external power source is attached to charge | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | * | 
|  | * Returns true if at least one of the chargers of the battery has an external | 
|  | * power source attached to charge the battery regardless of whether it is | 
|  | * actually charging or not. | 
|  | */ | 
|  | static bool is_ext_pwr_online(struct charger_manager *cm) | 
|  | { | 
|  | union power_supply_propval val; | 
|  | bool online = false; | 
|  | int i, ret; | 
|  |  | 
|  | /* If at least one of them has one, it's yes. */ | 
|  | for (i = 0; cm->charger_stat[i]; i++) { | 
|  | ret = cm->charger_stat[i]->get_property( | 
|  | cm->charger_stat[i], | 
|  | POWER_SUPPLY_PROP_ONLINE, &val); | 
|  | if (ret == 0 && val.intval) { | 
|  | online = true; | 
|  | break; | 
|  | } | 
|  | } | 
|  |  | 
|  | return online; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * get_batt_uV - Get the voltage level of the battery | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | * @uV: the voltage level returned. | 
|  | * | 
|  | * Returns 0 if there is no error. | 
|  | * Returns a negative value on error. | 
|  | */ | 
|  | static int get_batt_uV(struct charger_manager *cm, int *uV) | 
|  | { | 
|  | union power_supply_propval val; | 
|  | int ret; | 
|  |  | 
|  | if (!cm->fuel_gauge) | 
|  | return -ENODEV; | 
|  |  | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_VOLTAGE_NOW, &val); | 
|  | if (ret) | 
|  | return ret; | 
|  |  | 
|  | *uV = val.intval; | 
|  | return 0; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * is_charging - Returns true if the battery is being charged. | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | */ | 
|  | static bool is_charging(struct charger_manager *cm) | 
|  | { | 
|  | int i, ret; | 
|  | bool charging = false; | 
|  | union power_supply_propval val; | 
|  |  | 
|  | /* If there is no battery, it cannot be charged */ | 
|  | if (!is_batt_present(cm)) | 
|  | return false; | 
|  |  | 
|  | /* If at least one of the charger is charging, return yes */ | 
|  | for (i = 0; cm->charger_stat[i]; i++) { | 
|  | /* 1. The charger sholuld not be DISABLED */ | 
|  | if (cm->emergency_stop) | 
|  | continue; | 
|  | if (!cm->charger_enabled) | 
|  | continue; | 
|  |  | 
|  | /* 2. The charger should be online (ext-power) */ | 
|  | ret = cm->charger_stat[i]->get_property( | 
|  | cm->charger_stat[i], | 
|  | POWER_SUPPLY_PROP_ONLINE, &val); | 
|  | if (ret) { | 
|  | dev_warn(cm->dev, "Cannot read ONLINE value from %s.\n", | 
|  | cm->desc->psy_charger_stat[i]); | 
|  | continue; | 
|  | } | 
|  | if (val.intval == 0) | 
|  | continue; | 
|  |  | 
|  | /* | 
|  | * 3. The charger should not be FULL, DISCHARGING, | 
|  | * or NOT_CHARGING. | 
|  | */ | 
|  | ret = cm->charger_stat[i]->get_property( | 
|  | cm->charger_stat[i], | 
|  | POWER_SUPPLY_PROP_STATUS, &val); | 
|  | if (ret) { | 
|  | dev_warn(cm->dev, "Cannot read STATUS value from %s.\n", | 
|  | cm->desc->psy_charger_stat[i]); | 
|  | continue; | 
|  | } | 
|  | if (val.intval == POWER_SUPPLY_STATUS_FULL || | 
|  | val.intval == POWER_SUPPLY_STATUS_DISCHARGING || | 
|  | val.intval == POWER_SUPPLY_STATUS_NOT_CHARGING) | 
|  | continue; | 
|  |  | 
|  | /* Then, this is charging. */ | 
|  | charging = true; | 
|  | break; | 
|  | } | 
|  |  | 
|  | return charging; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * is_polling_required - Return true if need to continue polling for this CM. | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | */ | 
|  | static bool is_polling_required(struct charger_manager *cm) | 
|  | { | 
|  | switch (cm->desc->polling_mode) { | 
|  | case CM_POLL_DISABLE: | 
|  | return false; | 
|  | case CM_POLL_ALWAYS: | 
|  | return true; | 
|  | case CM_POLL_EXTERNAL_POWER_ONLY: | 
|  | return is_ext_pwr_online(cm); | 
|  | case CM_POLL_CHARGING_ONLY: | 
|  | return is_charging(cm); | 
|  | default: | 
|  | dev_warn(cm->dev, "Incorrect polling_mode (%d)\n", | 
|  | cm->desc->polling_mode); | 
|  | } | 
|  |  | 
|  | return false; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * try_charger_enable - Enable/Disable chargers altogether | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | * @enable: true: enable / false: disable | 
|  | * | 
|  | * Note that Charger Manager keeps the charger enabled regardless whether | 
|  | * the charger is charging or not (because battery is full or no external | 
|  | * power source exists) except when CM needs to disable chargers forcibly | 
|  | * bacause of emergency causes; when the battery is overheated or too cold. | 
|  | */ | 
|  | static int try_charger_enable(struct charger_manager *cm, bool enable) | 
|  | { | 
|  | int err = 0, i; | 
|  | struct charger_desc *desc = cm->desc; | 
|  |  | 
|  | /* Ignore if it's redundent command */ | 
|  | if (enable == cm->charger_enabled) | 
|  | return 0; | 
|  |  | 
|  | if (enable) { | 
|  | if (cm->emergency_stop) | 
|  | return -EAGAIN; | 
|  | err = regulator_bulk_enable(desc->num_charger_regulators, | 
|  | desc->charger_regulators); | 
|  | } else { | 
|  | /* | 
|  | * Abnormal battery state - Stop charging forcibly, | 
|  | * even if charger was enabled at the other places | 
|  | */ | 
|  | err = regulator_bulk_disable(desc->num_charger_regulators, | 
|  | desc->charger_regulators); | 
|  |  | 
|  | for (i = 0; i < desc->num_charger_regulators; i++) { | 
|  | if (regulator_is_enabled( | 
|  | desc->charger_regulators[i].consumer)) { | 
|  | regulator_force_disable( | 
|  | desc->charger_regulators[i].consumer); | 
|  | dev_warn(cm->dev, | 
|  | "Disable regulator(%s) forcibly.\n", | 
|  | desc->charger_regulators[i].supply); | 
|  | } | 
|  | } | 
|  | } | 
|  |  | 
|  | if (!err) | 
|  | cm->charger_enabled = enable; | 
|  |  | 
|  | return err; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * uevent_notify - Let users know something has changed. | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | * @event: the event string. | 
|  | * | 
|  | * If @event is null, it implies that uevent_notify is called | 
|  | * by resume function. When called in the resume function, cm_suspended | 
|  | * should be already reset to false in order to let uevent_notify | 
|  | * notify the recent event during the suspend to users. While | 
|  | * suspended, uevent_notify does not notify users, but tracks | 
|  | * events so that uevent_notify can notify users later after resumed. | 
|  | */ | 
|  | static void uevent_notify(struct charger_manager *cm, const char *event) | 
|  | { | 
|  | static char env_str[UEVENT_BUF_SIZE + 1] = ""; | 
|  | static char env_str_save[UEVENT_BUF_SIZE + 1] = ""; | 
|  |  | 
|  | if (cm_suspended) { | 
|  | /* Nothing in suspended-event buffer */ | 
|  | if (env_str_save[0] == 0) { | 
|  | if (!strncmp(env_str, event, UEVENT_BUF_SIZE)) | 
|  | return; /* status not changed */ | 
|  | strncpy(env_str_save, event, UEVENT_BUF_SIZE); | 
|  | return; | 
|  | } | 
|  |  | 
|  | if (!strncmp(env_str_save, event, UEVENT_BUF_SIZE)) | 
|  | return; /* Duplicated. */ | 
|  | strncpy(env_str_save, event, UEVENT_BUF_SIZE); | 
|  | return; | 
|  | } | 
|  |  | 
|  | if (event == NULL) { | 
|  | /* No messages pending */ | 
|  | if (!env_str_save[0]) | 
|  | return; | 
|  |  | 
|  | strncpy(env_str, env_str_save, UEVENT_BUF_SIZE); | 
|  | kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE); | 
|  | env_str_save[0] = 0; | 
|  |  | 
|  | return; | 
|  | } | 
|  |  | 
|  | /* status not changed */ | 
|  | if (!strncmp(env_str, event, UEVENT_BUF_SIZE)) | 
|  | return; | 
|  |  | 
|  | /* save the status and notify the update */ | 
|  | strncpy(env_str, event, UEVENT_BUF_SIZE); | 
|  | kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE); | 
|  |  | 
|  | dev_info(cm->dev, event); | 
|  | } | 
|  |  | 
|  | /** | 
|  | * _cm_monitor - Monitor the temperature and return true for exceptions. | 
|  | * @cm: the Charger Manager representing the battery. | 
|  | * | 
|  | * Returns true if there is an event to notify for the battery. | 
|  | * (True if the status of "emergency_stop" changes) | 
|  | */ | 
|  | static bool _cm_monitor(struct charger_manager *cm) | 
|  | { | 
|  | struct charger_desc *desc = cm->desc; | 
|  | int temp = desc->temperature_out_of_range(&cm->last_temp_mC); | 
|  |  | 
|  | dev_dbg(cm->dev, "monitoring (%2.2d.%3.3dC)\n", | 
|  | cm->last_temp_mC / 1000, cm->last_temp_mC % 1000); | 
|  |  | 
|  | /* It has been stopped or charging already */ | 
|  | if (!!temp == !!cm->emergency_stop) | 
|  | return false; | 
|  |  | 
|  | if (temp) { | 
|  | cm->emergency_stop = temp; | 
|  | if (!try_charger_enable(cm, false)) { | 
|  | if (temp > 0) | 
|  | uevent_notify(cm, "OVERHEAT"); | 
|  | else | 
|  | uevent_notify(cm, "COLD"); | 
|  | } | 
|  | } else { | 
|  | cm->emergency_stop = 0; | 
|  | if (!try_charger_enable(cm, true)) | 
|  | uevent_notify(cm, "CHARGING"); | 
|  | } | 
|  |  | 
|  | return true; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * cm_monitor - Monitor every battery. | 
|  | * | 
|  | * Returns true if there is an event to notify from any of the batteries. | 
|  | * (True if the status of "emergency_stop" changes) | 
|  | */ | 
|  | static bool cm_monitor(void) | 
|  | { | 
|  | bool stop = false; | 
|  | struct charger_manager *cm; | 
|  |  | 
|  | mutex_lock(&cm_list_mtx); | 
|  |  | 
|  | list_for_each_entry(cm, &cm_list, entry) { | 
|  | if (_cm_monitor(cm)) | 
|  | stop = true; | 
|  | } | 
|  |  | 
|  | mutex_unlock(&cm_list_mtx); | 
|  |  | 
|  | return stop; | 
|  | } | 
|  |  | 
|  | static int charger_get_property(struct power_supply *psy, | 
|  | enum power_supply_property psp, | 
|  | union power_supply_propval *val) | 
|  | { | 
|  | struct charger_manager *cm = container_of(psy, | 
|  | struct charger_manager, charger_psy); | 
|  | struct charger_desc *desc = cm->desc; | 
|  | int ret = 0; | 
|  | int uV; | 
|  |  | 
|  | switch (psp) { | 
|  | case POWER_SUPPLY_PROP_STATUS: | 
|  | if (is_charging(cm)) | 
|  | val->intval = POWER_SUPPLY_STATUS_CHARGING; | 
|  | else if (is_ext_pwr_online(cm)) | 
|  | val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; | 
|  | else | 
|  | val->intval = POWER_SUPPLY_STATUS_DISCHARGING; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_HEALTH: | 
|  | if (cm->emergency_stop > 0) | 
|  | val->intval = POWER_SUPPLY_HEALTH_OVERHEAT; | 
|  | else if (cm->emergency_stop < 0) | 
|  | val->intval = POWER_SUPPLY_HEALTH_COLD; | 
|  | else | 
|  | val->intval = POWER_SUPPLY_HEALTH_GOOD; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_PRESENT: | 
|  | if (is_batt_present(cm)) | 
|  | val->intval = 1; | 
|  | else | 
|  | val->intval = 0; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_VOLTAGE_NOW: | 
|  | ret = get_batt_uV(cm, &val->intval); | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_CURRENT_NOW: | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CURRENT_NOW, val); | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_TEMP: | 
|  | /* in thenth of centigrade */ | 
|  | if (cm->last_temp_mC == INT_MIN) | 
|  | desc->temperature_out_of_range(&cm->last_temp_mC); | 
|  | val->intval = cm->last_temp_mC / 100; | 
|  | if (!desc->measure_battery_temp) | 
|  | ret = -ENODEV; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_TEMP_AMBIENT: | 
|  | /* in thenth of centigrade */ | 
|  | if (cm->last_temp_mC == INT_MIN) | 
|  | desc->temperature_out_of_range(&cm->last_temp_mC); | 
|  | val->intval = cm->last_temp_mC / 100; | 
|  | if (desc->measure_battery_temp) | 
|  | ret = -ENODEV; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_CAPACITY: | 
|  | if (!cm->fuel_gauge) { | 
|  | ret = -ENODEV; | 
|  | break; | 
|  | } | 
|  |  | 
|  | if (!is_batt_present(cm)) { | 
|  | /* There is no battery. Assume 100% */ | 
|  | val->intval = 100; | 
|  | break; | 
|  | } | 
|  |  | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CAPACITY, val); | 
|  | if (ret) | 
|  | break; | 
|  |  | 
|  | if (val->intval > 100) { | 
|  | val->intval = 100; | 
|  | break; | 
|  | } | 
|  | if (val->intval < 0) | 
|  | val->intval = 0; | 
|  |  | 
|  | /* Do not adjust SOC when charging: voltage is overrated */ | 
|  | if (is_charging(cm)) | 
|  | break; | 
|  |  | 
|  | /* | 
|  | * If the capacity value is inconsistent, calibrate it base on | 
|  | * the battery voltage values and the thresholds given as desc | 
|  | */ | 
|  | ret = get_batt_uV(cm, &uV); | 
|  | if (ret) { | 
|  | /* Voltage information not available. No calibration */ | 
|  | ret = 0; | 
|  | break; | 
|  | } | 
|  |  | 
|  | if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV && | 
|  | !is_charging(cm)) { | 
|  | val->intval = 100; | 
|  | break; | 
|  | } | 
|  |  | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_ONLINE: | 
|  | if (is_ext_pwr_online(cm)) | 
|  | val->intval = 1; | 
|  | else | 
|  | val->intval = 0; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_CHARGE_FULL: | 
|  | if (cm->fuel_gauge) { | 
|  | if (cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0) | 
|  | break; | 
|  | } | 
|  |  | 
|  | if (is_ext_pwr_online(cm)) { | 
|  | /* Not full if it's charging. */ | 
|  | if (is_charging(cm)) { | 
|  | val->intval = 0; | 
|  | break; | 
|  | } | 
|  | /* | 
|  | * Full if it's powered but not charging andi | 
|  | * not forced stop by emergency | 
|  | */ | 
|  | if (!cm->emergency_stop) { | 
|  | val->intval = 1; | 
|  | break; | 
|  | } | 
|  | } | 
|  |  | 
|  | /* Full if it's over the fullbatt voltage */ | 
|  | ret = get_batt_uV(cm, &uV); | 
|  | if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV && | 
|  | !is_charging(cm)) { | 
|  | val->intval = 1; | 
|  | break; | 
|  | } | 
|  |  | 
|  | /* Full if the cap is 100 */ | 
|  | if (cm->fuel_gauge) { | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CAPACITY, val); | 
|  | if (!ret && val->intval >= 100 && !is_charging(cm)) { | 
|  | val->intval = 1; | 
|  | break; | 
|  | } | 
|  | } | 
|  |  | 
|  | val->intval = 0; | 
|  | ret = 0; | 
|  | break; | 
|  | case POWER_SUPPLY_PROP_CHARGE_NOW: | 
|  | if (is_charging(cm)) { | 
|  | ret = cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CHARGE_NOW, | 
|  | val); | 
|  | if (ret) { | 
|  | val->intval = 1; | 
|  | ret = 0; | 
|  | } else { | 
|  | /* If CHARGE_NOW is supplied, use it */ | 
|  | val->intval = (val->intval > 0) ? | 
|  | val->intval : 1; | 
|  | } | 
|  | } else { | 
|  | val->intval = 0; | 
|  | } | 
|  | break; | 
|  | default: | 
|  | return -EINVAL; | 
|  | } | 
|  | return ret; | 
|  | } | 
|  |  | 
|  | #define NUM_CHARGER_PSY_OPTIONAL	(4) | 
|  | static enum power_supply_property default_charger_props[] = { | 
|  | /* Guaranteed to provide */ | 
|  | POWER_SUPPLY_PROP_STATUS, | 
|  | POWER_SUPPLY_PROP_HEALTH, | 
|  | POWER_SUPPLY_PROP_PRESENT, | 
|  | POWER_SUPPLY_PROP_VOLTAGE_NOW, | 
|  | POWER_SUPPLY_PROP_CAPACITY, | 
|  | POWER_SUPPLY_PROP_ONLINE, | 
|  | POWER_SUPPLY_PROP_CHARGE_FULL, | 
|  | /* | 
|  | * Optional properties are: | 
|  | * POWER_SUPPLY_PROP_CHARGE_NOW, | 
|  | * POWER_SUPPLY_PROP_CURRENT_NOW, | 
|  | * POWER_SUPPLY_PROP_TEMP, and | 
|  | * POWER_SUPPLY_PROP_TEMP_AMBIENT, | 
|  | */ | 
|  | }; | 
|  |  | 
|  | static struct power_supply psy_default = { | 
|  | .name = "battery", | 
|  | .type = POWER_SUPPLY_TYPE_BATTERY, | 
|  | .properties = default_charger_props, | 
|  | .num_properties = ARRAY_SIZE(default_charger_props), | 
|  | .get_property = charger_get_property, | 
|  | }; | 
|  |  | 
|  | /** | 
|  | * cm_setup_timer - For in-suspend monitoring setup wakeup alarm | 
|  | *		    for suspend_again. | 
|  | * | 
|  | * Returns true if the alarm is set for Charger Manager to use. | 
|  | * Returns false if | 
|  | *	cm_setup_timer fails to set an alarm, | 
|  | *	cm_setup_timer does not need to set an alarm for Charger Manager, | 
|  | *	or an alarm previously configured is to be used. | 
|  | */ | 
|  | static bool cm_setup_timer(void) | 
|  | { | 
|  | struct charger_manager *cm; | 
|  | unsigned int wakeup_ms = UINT_MAX; | 
|  | bool ret = false; | 
|  |  | 
|  | mutex_lock(&cm_list_mtx); | 
|  |  | 
|  | list_for_each_entry(cm, &cm_list, entry) { | 
|  | /* Skip if polling is not required for this CM */ | 
|  | if (!is_polling_required(cm) && !cm->emergency_stop) | 
|  | continue; | 
|  | if (cm->desc->polling_interval_ms == 0) | 
|  | continue; | 
|  | CM_MIN_VALID(wakeup_ms, cm->desc->polling_interval_ms); | 
|  | } | 
|  |  | 
|  | mutex_unlock(&cm_list_mtx); | 
|  |  | 
|  | if (wakeup_ms < UINT_MAX && wakeup_ms > 0) { | 
|  | pr_info("Charger Manager wakeup timer: %u ms.\n", wakeup_ms); | 
|  | if (rtc_dev) { | 
|  | struct rtc_wkalrm tmp; | 
|  | unsigned long time, now; | 
|  | unsigned long add = DIV_ROUND_UP(wakeup_ms, 1000); | 
|  |  | 
|  | /* | 
|  | * Set alarm with the polling interval (wakeup_ms) | 
|  | * except when rtc_wkalarm_save comes first. | 
|  | * However, the alarm time should be NOW + | 
|  | * CM_RTC_SMALL or later. | 
|  | */ | 
|  | tmp.enabled = 1; | 
|  | rtc_read_time(rtc_dev, &tmp.time); | 
|  | rtc_tm_to_time(&tmp.time, &now); | 
|  | if (add < CM_RTC_SMALL) | 
|  | add = CM_RTC_SMALL; | 
|  | time = now + add; | 
|  |  | 
|  | ret = true; | 
|  |  | 
|  | if (rtc_wkalarm_save.enabled && | 
|  | rtc_wkalarm_save_time && | 
|  | rtc_wkalarm_save_time < time) { | 
|  | if (rtc_wkalarm_save_time < now + CM_RTC_SMALL) | 
|  | time = now + CM_RTC_SMALL; | 
|  | else | 
|  | time = rtc_wkalarm_save_time; | 
|  |  | 
|  | /* The timer is not appointed by CM */ | 
|  | ret = false; | 
|  | } | 
|  |  | 
|  | pr_info("Waking up after %lu secs.\n", | 
|  | time - now); | 
|  |  | 
|  | rtc_time_to_tm(time, &tmp.time); | 
|  | rtc_set_alarm(rtc_dev, &tmp); | 
|  | cm_suspend_duration_ms += wakeup_ms; | 
|  | return ret; | 
|  | } | 
|  | } | 
|  |  | 
|  | if (rtc_dev) | 
|  | rtc_set_alarm(rtc_dev, &rtc_wkalarm_save); | 
|  | return false; | 
|  | } | 
|  |  | 
|  | /** | 
|  | * cm_suspend_again - Determine whether suspend again or not | 
|  | * | 
|  | * Returns true if the system should be suspended again | 
|  | * Returns false if the system should be woken up | 
|  | */ | 
|  | bool cm_suspend_again(void) | 
|  | { | 
|  | struct charger_manager *cm; | 
|  | bool ret = false; | 
|  |  | 
|  | if (!g_desc || !g_desc->rtc_only_wakeup || !g_desc->rtc_only_wakeup() || | 
|  | !cm_rtc_set) | 
|  | return false; | 
|  |  | 
|  | if (cm_monitor()) | 
|  | goto out; | 
|  |  | 
|  | ret = true; | 
|  | mutex_lock(&cm_list_mtx); | 
|  | list_for_each_entry(cm, &cm_list, entry) { | 
|  | if (cm->status_save_ext_pwr_inserted != is_ext_pwr_online(cm) || | 
|  | cm->status_save_batt != is_batt_present(cm)) { | 
|  | ret = false; | 
|  | break; | 
|  | } | 
|  | } | 
|  | mutex_unlock(&cm_list_mtx); | 
|  |  | 
|  | cm_rtc_set = cm_setup_timer(); | 
|  | out: | 
|  | /* It's about the time when the non-CM appointed timer goes off */ | 
|  | if (rtc_wkalarm_save.enabled) { | 
|  | unsigned long now; | 
|  | struct rtc_time tmp; | 
|  |  | 
|  | rtc_read_time(rtc_dev, &tmp); | 
|  | rtc_tm_to_time(&tmp, &now); | 
|  |  | 
|  | if (rtc_wkalarm_save_time && | 
|  | now + CM_RTC_SMALL >= rtc_wkalarm_save_time) | 
|  | return false; | 
|  | } | 
|  | return ret; | 
|  | } | 
|  | EXPORT_SYMBOL_GPL(cm_suspend_again); | 
|  |  | 
|  | /** | 
|  | * setup_charger_manager - initialize charger_global_desc data | 
|  | * @gd: pointer to instance of charger_global_desc | 
|  | */ | 
|  | int setup_charger_manager(struct charger_global_desc *gd) | 
|  | { | 
|  | if (!gd) | 
|  | return -EINVAL; | 
|  |  | 
|  | if (rtc_dev) | 
|  | rtc_class_close(rtc_dev); | 
|  | rtc_dev = NULL; | 
|  | g_desc = NULL; | 
|  |  | 
|  | if (!gd->rtc_only_wakeup) { | 
|  | pr_err("The callback rtc_only_wakeup is not given.\n"); | 
|  | return -EINVAL; | 
|  | } | 
|  |  | 
|  | if (gd->rtc_name) { | 
|  | rtc_dev = rtc_class_open(gd->rtc_name); | 
|  | if (IS_ERR_OR_NULL(rtc_dev)) { | 
|  | rtc_dev = NULL; | 
|  | /* Retry at probe. RTC may be not registered yet */ | 
|  | } | 
|  | } else { | 
|  | pr_warn("No wakeup timer is given for charger manager." | 
|  | "In-suspend monitoring won't work.\n"); | 
|  | } | 
|  |  | 
|  | g_desc = gd; | 
|  | return 0; | 
|  | } | 
|  | EXPORT_SYMBOL_GPL(setup_charger_manager); | 
|  |  | 
|  | static int charger_manager_probe(struct platform_device *pdev) | 
|  | { | 
|  | struct charger_desc *desc = dev_get_platdata(&pdev->dev); | 
|  | struct charger_manager *cm; | 
|  | int ret = 0, i = 0; | 
|  | union power_supply_propval val; | 
|  |  | 
|  | if (g_desc && !rtc_dev && g_desc->rtc_name) { | 
|  | rtc_dev = rtc_class_open(g_desc->rtc_name); | 
|  | if (IS_ERR_OR_NULL(rtc_dev)) { | 
|  | rtc_dev = NULL; | 
|  | dev_err(&pdev->dev, "Cannot get RTC %s.\n", | 
|  | g_desc->rtc_name); | 
|  | ret = -ENODEV; | 
|  | goto err_alloc; | 
|  | } | 
|  | } | 
|  |  | 
|  | if (!desc) { | 
|  | dev_err(&pdev->dev, "No platform data (desc) found.\n"); | 
|  | ret = -ENODEV; | 
|  | goto err_alloc; | 
|  | } | 
|  |  | 
|  | cm = kzalloc(sizeof(struct charger_manager), GFP_KERNEL); | 
|  | if (!cm) { | 
|  | dev_err(&pdev->dev, "Cannot allocate memory.\n"); | 
|  | ret = -ENOMEM; | 
|  | goto err_alloc; | 
|  | } | 
|  |  | 
|  | /* Basic Values. Unspecified are Null or 0 */ | 
|  | cm->dev = &pdev->dev; | 
|  | cm->desc = kzalloc(sizeof(struct charger_desc), GFP_KERNEL); | 
|  | if (!cm->desc) { | 
|  | dev_err(&pdev->dev, "Cannot allocate memory.\n"); | 
|  | ret = -ENOMEM; | 
|  | goto err_alloc_desc; | 
|  | } | 
|  | memcpy(cm->desc, desc, sizeof(struct charger_desc)); | 
|  | cm->last_temp_mC = INT_MIN; /* denotes "unmeasured, yet" */ | 
|  |  | 
|  | if (!desc->charger_regulators || desc->num_charger_regulators < 1) { | 
|  | ret = -EINVAL; | 
|  | dev_err(&pdev->dev, "charger_regulators undefined.\n"); | 
|  | goto err_no_charger; | 
|  | } | 
|  |  | 
|  | if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) { | 
|  | dev_err(&pdev->dev, "No power supply defined.\n"); | 
|  | ret = -EINVAL; | 
|  | goto err_no_charger_stat; | 
|  | } | 
|  |  | 
|  | /* Counting index only */ | 
|  | while (desc->psy_charger_stat[i]) | 
|  | i++; | 
|  |  | 
|  | cm->charger_stat = kzalloc(sizeof(struct power_supply *) * (i + 1), | 
|  | GFP_KERNEL); | 
|  | if (!cm->charger_stat) { | 
|  | ret = -ENOMEM; | 
|  | goto err_no_charger_stat; | 
|  | } | 
|  |  | 
|  | for (i = 0; desc->psy_charger_stat[i]; i++) { | 
|  | cm->charger_stat[i] = power_supply_get_by_name( | 
|  | desc->psy_charger_stat[i]); | 
|  | if (!cm->charger_stat[i]) { | 
|  | dev_err(&pdev->dev, "Cannot find power supply " | 
|  | "\"%s\"\n", | 
|  | desc->psy_charger_stat[i]); | 
|  | ret = -ENODEV; | 
|  | goto err_chg_stat; | 
|  | } | 
|  | } | 
|  |  | 
|  | cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); | 
|  | if (!cm->fuel_gauge) { | 
|  | dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", | 
|  | desc->psy_fuel_gauge); | 
|  | ret = -ENODEV; | 
|  | goto err_chg_stat; | 
|  | } | 
|  |  | 
|  | if (desc->polling_interval_ms == 0 || | 
|  | msecs_to_jiffies(desc->polling_interval_ms) <= CM_JIFFIES_SMALL) { | 
|  | dev_err(&pdev->dev, "polling_interval_ms is too small\n"); | 
|  | ret = -EINVAL; | 
|  | goto err_chg_stat; | 
|  | } | 
|  |  | 
|  | if (!desc->temperature_out_of_range) { | 
|  | dev_err(&pdev->dev, "there is no temperature_out_of_range\n"); | 
|  | ret = -EINVAL; | 
|  | goto err_chg_stat; | 
|  | } | 
|  |  | 
|  | platform_set_drvdata(pdev, cm); | 
|  |  | 
|  | memcpy(&cm->charger_psy, &psy_default, sizeof(psy_default)); | 
|  |  | 
|  | if (!desc->psy_name) { | 
|  | strncpy(cm->psy_name_buf, psy_default.name, PSY_NAME_MAX); | 
|  | } else { | 
|  | strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX); | 
|  | } | 
|  | cm->charger_psy.name = cm->psy_name_buf; | 
|  |  | 
|  | /* Allocate for psy properties because they may vary */ | 
|  | cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property) | 
|  | * (ARRAY_SIZE(default_charger_props) + | 
|  | NUM_CHARGER_PSY_OPTIONAL), | 
|  | GFP_KERNEL); | 
|  | if (!cm->charger_psy.properties) { | 
|  | dev_err(&pdev->dev, "Cannot allocate for psy properties.\n"); | 
|  | ret = -ENOMEM; | 
|  | goto err_chg_stat; | 
|  | } | 
|  | memcpy(cm->charger_psy.properties, default_charger_props, | 
|  | sizeof(enum power_supply_property) * | 
|  | ARRAY_SIZE(default_charger_props)); | 
|  | cm->charger_psy.num_properties = psy_default.num_properties; | 
|  |  | 
|  | /* Find which optional psy-properties are available */ | 
|  | if (!cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CHARGE_NOW, &val)) { | 
|  | cm->charger_psy.properties[cm->charger_psy.num_properties] = | 
|  | POWER_SUPPLY_PROP_CHARGE_NOW; | 
|  | cm->charger_psy.num_properties++; | 
|  | } | 
|  | if (!cm->fuel_gauge->get_property(cm->fuel_gauge, | 
|  | POWER_SUPPLY_PROP_CURRENT_NOW, | 
|  | &val)) { | 
|  | cm->charger_psy.properties[cm->charger_psy.num_properties] = | 
|  | POWER_SUPPLY_PROP_CURRENT_NOW; | 
|  | cm->charger_psy.num_properties++; | 
|  | } | 
|  |  | 
|  | if (desc->measure_battery_temp) { | 
|  | cm->charger_psy.properties[cm->charger_psy.num_properties] = | 
|  | POWER_SUPPLY_PROP_TEMP; | 
|  | cm->charger_psy.num_properties++; | 
|  | } else { | 
|  | cm->charger_psy.properties[cm->charger_psy.num_properties] = | 
|  | POWER_SUPPLY_PROP_TEMP_AMBIENT; | 
|  | cm->charger_psy.num_properties++; | 
|  | } | 
|  |  | 
|  | ret = power_supply_register(NULL, &cm->charger_psy); | 
|  | if (ret) { | 
|  | dev_err(&pdev->dev, "Cannot register charger-manager with" | 
|  | " name \"%s\".\n", cm->charger_psy.name); | 
|  | goto err_register; | 
|  | } | 
|  |  | 
|  | ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators, | 
|  | desc->charger_regulators); | 
|  | if (ret) { | 
|  | dev_err(&pdev->dev, "Cannot get charger regulators.\n"); | 
|  | goto err_bulk_get; | 
|  | } | 
|  |  | 
|  | ret = try_charger_enable(cm, true); | 
|  | if (ret) { | 
|  | dev_err(&pdev->dev, "Cannot enable charger regulators\n"); | 
|  | goto err_chg_enable; | 
|  | } | 
|  |  | 
|  | /* Add to the list */ | 
|  | mutex_lock(&cm_list_mtx); | 
|  | list_add(&cm->entry, &cm_list); | 
|  | mutex_unlock(&cm_list_mtx); | 
|  |  | 
|  | return 0; | 
|  |  | 
|  | err_chg_enable: | 
|  | regulator_bulk_free(desc->num_charger_regulators, | 
|  | desc->charger_regulators); | 
|  | err_bulk_get: | 
|  | power_supply_unregister(&cm->charger_psy); | 
|  | err_register: | 
|  | kfree(cm->charger_psy.properties); | 
|  | err_chg_stat: | 
|  | kfree(cm->charger_stat); | 
|  | err_no_charger_stat: | 
|  | err_no_charger: | 
|  | kfree(cm->desc); | 
|  | err_alloc_desc: | 
|  | kfree(cm); | 
|  | err_alloc: | 
|  | return ret; | 
|  | } | 
|  |  | 
|  | static int __devexit charger_manager_remove(struct platform_device *pdev) | 
|  | { | 
|  | struct charger_manager *cm = platform_get_drvdata(pdev); | 
|  | struct charger_desc *desc = cm->desc; | 
|  |  | 
|  | /* Remove from the list */ | 
|  | mutex_lock(&cm_list_mtx); | 
|  | list_del(&cm->entry); | 
|  | mutex_unlock(&cm_list_mtx); | 
|  |  | 
|  | regulator_bulk_free(desc->num_charger_regulators, | 
|  | desc->charger_regulators); | 
|  | power_supply_unregister(&cm->charger_psy); | 
|  | kfree(cm->charger_psy.properties); | 
|  | kfree(cm->charger_stat); | 
|  | kfree(cm->desc); | 
|  | kfree(cm); | 
|  |  | 
|  | return 0; | 
|  | } | 
|  |  | 
|  | static const struct platform_device_id charger_manager_id[] = { | 
|  | { "charger-manager", 0 }, | 
|  | { }, | 
|  | }; | 
|  | MODULE_DEVICE_TABLE(platform, charger_manager_id); | 
|  |  | 
|  | static int cm_suspend_prepare(struct device *dev) | 
|  | { | 
|  | struct charger_manager *cm = dev_get_drvdata(dev); | 
|  |  | 
|  | if (!cm_suspended) { | 
|  | if (rtc_dev) { | 
|  | struct rtc_time tmp; | 
|  | unsigned long now; | 
|  |  | 
|  | rtc_read_alarm(rtc_dev, &rtc_wkalarm_save); | 
|  | rtc_read_time(rtc_dev, &tmp); | 
|  |  | 
|  | if (rtc_wkalarm_save.enabled) { | 
|  | rtc_tm_to_time(&rtc_wkalarm_save.time, | 
|  | &rtc_wkalarm_save_time); | 
|  | rtc_tm_to_time(&tmp, &now); | 
|  | if (now > rtc_wkalarm_save_time) | 
|  | rtc_wkalarm_save_time = 0; | 
|  | } else { | 
|  | rtc_wkalarm_save_time = 0; | 
|  | } | 
|  | } | 
|  | cm_suspended = true; | 
|  | } | 
|  |  | 
|  | cm->status_save_ext_pwr_inserted = is_ext_pwr_online(cm); | 
|  | cm->status_save_batt = is_batt_present(cm); | 
|  |  | 
|  | if (!cm_rtc_set) { | 
|  | cm_suspend_duration_ms = 0; | 
|  | cm_rtc_set = cm_setup_timer(); | 
|  | } | 
|  |  | 
|  | return 0; | 
|  | } | 
|  |  | 
|  | static void cm_suspend_complete(struct device *dev) | 
|  | { | 
|  | struct charger_manager *cm = dev_get_drvdata(dev); | 
|  |  | 
|  | if (cm_suspended) { | 
|  | if (rtc_dev) { | 
|  | struct rtc_wkalrm tmp; | 
|  |  | 
|  | rtc_read_alarm(rtc_dev, &tmp); | 
|  | rtc_wkalarm_save.pending = tmp.pending; | 
|  | rtc_set_alarm(rtc_dev, &rtc_wkalarm_save); | 
|  | } | 
|  | cm_suspended = false; | 
|  | cm_rtc_set = false; | 
|  | } | 
|  |  | 
|  | uevent_notify(cm, NULL); | 
|  | } | 
|  |  | 
|  | static const struct dev_pm_ops charger_manager_pm = { | 
|  | .prepare	= cm_suspend_prepare, | 
|  | .complete	= cm_suspend_complete, | 
|  | }; | 
|  |  | 
|  | static struct platform_driver charger_manager_driver = { | 
|  | .driver = { | 
|  | .name = "charger-manager", | 
|  | .owner = THIS_MODULE, | 
|  | .pm = &charger_manager_pm, | 
|  | }, | 
|  | .probe = charger_manager_probe, | 
|  | .remove = __devexit_p(charger_manager_remove), | 
|  | .id_table = charger_manager_id, | 
|  | }; | 
|  |  | 
|  | static int __init charger_manager_init(void) | 
|  | { | 
|  | return platform_driver_register(&charger_manager_driver); | 
|  | } | 
|  | late_initcall(charger_manager_init); | 
|  |  | 
|  | static void __exit charger_manager_cleanup(void) | 
|  | { | 
|  | platform_driver_unregister(&charger_manager_driver); | 
|  | } | 
|  | module_exit(charger_manager_cleanup); | 
|  |  | 
|  | MODULE_AUTHOR("MyungJoo Ham <myungjoo.ham@samsung.com>"); | 
|  | MODULE_DESCRIPTION("Charger Manager"); | 
|  | MODULE_LICENSE("GPL"); |