| Per Liden | b97bf3f | 2006-01-02 19:04:38 +0100 | [diff] [blame] | 1 | # | 
|  | 2 | # TIPC configuration | 
|  | 3 | # | 
|  | 4 |  | 
|  | 5 | menu "TIPC Configuration (EXPERIMENTAL)" | 
|  | 6 | depends on INET && EXPERIMENTAL | 
|  | 7 |  | 
|  | 8 | config TIPC | 
|  | 9 | tristate "The TIPC Protocol (EXPERIMENTAL)" | 
|  | 10 | ---help--- | 
| Per Liden | c11ac3f | 2006-01-16 16:32:18 +0100 | [diff] [blame] | 11 | The Transparent Inter Process Communication (TIPC) protocol is | 
|  | 12 | specially designed for intra cluster communication. This protocol | 
|  | 13 | originates from Ericsson where it has been used in carrier grade | 
|  | 14 | cluster applications for many years. | 
|  | 15 |  | 
|  | 16 | For more information about TIPC, see http://tipc.sourceforge.net. | 
| Per Liden | b97bf3f | 2006-01-02 19:04:38 +0100 | [diff] [blame] | 17 |  | 
|  | 18 | This protocol support is also available as a module ( = code which | 
|  | 19 | can be inserted in and removed from the running kernel whenever you | 
|  | 20 | want). The module will be called tipc. If you want to compile it | 
|  | 21 | as a module, say M here and read <file:Documentation/modules.txt>. | 
|  | 22 |  | 
|  | 23 | If in doubt, say N. | 
|  | 24 |  | 
|  | 25 | config TIPC_ADVANCED | 
|  | 26 | bool "TIPC: Advanced configuration" | 
|  | 27 | depends on TIPC | 
|  | 28 | default n | 
|  | 29 | help | 
|  | 30 | Saying Y here will open some advanced configuration | 
|  | 31 | for TIPC. Most users do not need to bother, so if | 
|  | 32 | unsure, just say N. | 
|  | 33 |  | 
|  | 34 | config TIPC_ZONES | 
|  | 35 | int "Maximum number of zones in network" | 
|  | 36 | depends on TIPC && TIPC_ADVANCED | 
|  | 37 | default "3" | 
|  | 38 | help | 
|  | 39 | Max number of zones inside TIPC network. Max supported value | 
|  | 40 | is 255 zones, minimum is 1 | 
|  | 41 |  | 
|  | 42 | Default is 3 zones in a network; setting this to higher | 
|  | 43 | allows more zones but might use more memory. | 
|  | 44 |  | 
|  | 45 | config TIPC_CLUSTERS | 
|  | 46 | int "Maximum number of clusters in a zone" | 
|  | 47 | depends on TIPC && TIPC_ADVANCED | 
|  | 48 | default "1" | 
|  | 49 | help | 
|  | 50 | ***Only 1 (one cluster in a zone) is supported by current code. | 
|  | 51 | Any value set here will be overridden.*** | 
|  | 52 |  | 
|  | 53 | (Max number of clusters inside TIPC zone. Max supported | 
|  | 54 | value is 4095 clusters, minimum is 1. | 
|  | 55 |  | 
|  | 56 | Default is 1; setting this to smaller value might save | 
|  | 57 | some memory, setting it to higher | 
|  | 58 | allows more clusters and might consume more memory.) | 
|  | 59 |  | 
|  | 60 | config TIPC_NODES | 
|  | 61 | int "Maximum number of nodes in cluster" | 
|  | 62 | depends on TIPC && TIPC_ADVANCED | 
|  | 63 | default "255" | 
|  | 64 | help | 
|  | 65 | Maximum number of nodes inside a TIPC cluster. Maximum | 
|  | 66 | supported value is 2047 nodes, minimum is 8. | 
|  | 67 |  | 
|  | 68 | Setting this to a smaller value saves some memory, | 
|  | 69 | setting it to higher allows more nodes. | 
|  | 70 |  | 
|  | 71 | config TIPC_SLAVE_NODES | 
|  | 72 | int "Maximum number of slave nodes in cluster" | 
|  | 73 | depends on TIPC && TIPC_ADVANCED | 
|  | 74 | default "0" | 
|  | 75 | help | 
|  | 76 | ***This capability is not supported by current code.*** | 
|  | 77 |  | 
|  | 78 | Maximum number of slave nodes inside a TIPC cluster. Maximum | 
|  | 79 | supported value is 2047 nodes, minimum is 0. | 
|  | 80 |  | 
|  | 81 | Setting this to a smaller value saves some memory, | 
|  | 82 | setting it to higher allows more nodes. | 
|  | 83 |  | 
|  | 84 | config TIPC_PORTS | 
|  | 85 | int "Maximum number of ports in a node" | 
|  | 86 | depends on TIPC && TIPC_ADVANCED | 
|  | 87 | default "8191" | 
|  | 88 | help | 
|  | 89 | Maximum number of ports within a node. Maximum | 
|  | 90 | supported value is 64535 nodes, minimum is 127. | 
|  | 91 |  | 
|  | 92 | Setting this to a smaller value saves some memory, | 
|  | 93 | setting it to higher allows more ports. | 
|  | 94 |  | 
|  | 95 | config TIPC_LOG | 
|  | 96 | int "Size of log buffer" | 
|  | 97 | depends on TIPC && TIPC_ADVANCED | 
|  | 98 | default 0 | 
|  | 99 | help | 
|  | 100 | Size (in bytes) of TIPC's internal log buffer, which records the | 
|  | 101 | occurrence of significant events.  Maximum supported value | 
|  | 102 | is 32768 bytes, minimum is 0. | 
|  | 103 |  | 
|  | 104 | There is no need to enable the log buffer unless the node will be | 
|  | 105 | managed remotely via TIPC. | 
|  | 106 |  | 
|  | 107 | config TIPC_DEBUG | 
|  | 108 | bool "Enable debugging support" | 
|  | 109 | depends on TIPC | 
|  | 110 | default n | 
|  | 111 | help | 
|  | 112 | This will enable debugging of TIPC. | 
|  | 113 |  | 
|  | 114 | Only say Y here if you are having trouble with TIPC.  It will | 
|  | 115 | enable the display of detailed information about what is going on. | 
|  | 116 |  | 
|  | 117 | endmenu |