| stigge@antcom.de | a5b79d6 | 2011-01-20 18:42:55 +0100 | [diff] [blame] | 1 | Kernel driver max6639 | 
|  | 2 | ===================== | 
|  | 3 |  | 
|  | 4 | Supported chips: | 
|  | 5 | * Maxim MAX6639 | 
|  | 6 | Prefix: 'max6639' | 
|  | 7 | Addresses scanned: I2C 0x2c, 0x2e, 0x2f | 
|  | 8 | Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf | 
|  | 9 |  | 
|  | 10 | Authors: | 
|  | 11 | He Changqing <hechangqing@semptian.com> | 
|  | 12 | Roland Stigge <stigge@antcom.de> | 
|  | 13 |  | 
|  | 14 | Description | 
|  | 15 | ----------- | 
|  | 16 |  | 
|  | 17 | This driver implements support for the Maxim MAX6639. This chip is a 2-channel | 
|  | 18 | temperature monitor with dual PWM fan speed controller. It can monitor its own | 
|  | 19 | temperature and one external diode-connected transistor or two external | 
|  | 20 | diode-connected transistors. | 
|  | 21 |  | 
|  | 22 | The following device attributes are implemented via sysfs: | 
|  | 23 |  | 
|  | 24 | Attribute              R/W  Contents | 
|  | 25 | ---------------------------------------------------------------------------- | 
|  | 26 | temp1_input            R    Temperature channel 1 input (0..150 C) | 
|  | 27 | temp2_input            R    Temperature channel 2 input (0..150 C) | 
|  | 28 | temp1_fault            R    Temperature channel 1 diode fault | 
|  | 29 | temp2_fault            R    Temperature channel 2 diode fault | 
|  | 30 | temp1_max              RW   Set THERM temperature for input 1 | 
|  | 31 | (in C, see datasheet) | 
|  | 32 | temp2_max              RW   Set THERM temperature for input 2 | 
|  | 33 | temp1_crit             RW   Set ALERT temperature for input 1 | 
|  | 34 | temp2_crit             RW   Set ALERT temperature for input 2 | 
|  | 35 | temp1_emergency        RW   Set OT temperature for input 1 | 
|  | 36 | (in C, see datasheet) | 
|  | 37 | temp2_emergency        RW   Set OT temperature for input 2 | 
|  | 38 | pwm1                   RW   Fan 1 target duty cycle (0..255) | 
|  | 39 | pwm2                   RW   Fan 2 target duty cycle (0..255) | 
|  | 40 | fan1_input             R    TACH1 fan tachometer input (in RPM) | 
|  | 41 | fan2_input             R    TACH2 fan tachometer input (in RPM) | 
|  | 42 | fan1_fault             R    Fan 1 fault | 
|  | 43 | fan2_fault             R    Fan 2 fault | 
|  | 44 | temp1_max_alarm        R    Alarm on THERM temperature on channel 1 | 
|  | 45 | temp2_max_alarm        R    Alarm on THERM temperature on channel 2 | 
|  | 46 | temp1_crit_alarm       R    Alarm on ALERT temperature on channel 1 | 
|  | 47 | temp2_crit_alarm       R    Alarm on ALERT temperature on channel 2 | 
|  | 48 | temp1_emergency_alarm  R    Alarm on OT temperature on channel 1 | 
|  | 49 | temp2_emergency_alarm  R    Alarm on OT temperature on channel 2 |