OMAPDSS: DISPC/APPLY: Use interlace info in manager timings for dispc_ovl_setup()
Currently the interlace parameter passed to dispc_ovl_setup() is configured by
checking the display type, and set to true if the display type is VENC.
This isn't correct as other panels can take interlaced content too. The
omap_video_timings struct in manager's private data contains the info whether
the panel is in interlaced mode or not.
Signed-off-by: Archit Taneja <archit@ti.com>
diff --git a/drivers/video/omap2/dss/dispc.c b/drivers/video/omap2/dss/dispc.c
index d200f44..d1a7a0c 100644
--- a/drivers/video/omap2/dss/dispc.c
+++ b/drivers/video/omap2/dss/dispc.c
@@ -2157,8 +2157,7 @@
}
int dispc_ovl_setup(enum omap_plane plane, struct omap_overlay_info *oi,
- bool ilace, bool replication,
- const struct omap_video_timings *mgr_timings)
+ bool replication, const struct omap_video_timings *mgr_timings)
{
struct omap_overlay *ovl = omap_dss_get_overlay(plane);
bool five_taps = true;
@@ -2174,6 +2173,7 @@
u16 out_width, out_height;
enum omap_channel channel;
int x_predecim = 1, y_predecim = 1;
+ bool ilace = mgr_timings->interlace;
channel = dispc_ovl_get_channel_out(plane);