powerpc/85xx: Don't scan for TBI PHY addresses on MPC8569E-MDS boards
Sometimes (e.g. when there are no UEMs attached to a board)
fsl_pq_mdio_find_free() fails to find a spare address for a TBI PHY,
this is because get_phy_id() returns bogus 0x0000ffff values
(0xffffffff is expected), and therefore mdio bus probing fails with
the following message:
fsl-pq_mdio: probe of e0082120.mdio failed with error -16
And obviously ethernet doesn't work after this.
This patch solves the problem by adding tbi-phy node into mdio node,
so that we won't scan for spare addresses, we'll just use a fixed one.
Signed-off-by: Anton Vorontsov <avorontsov@ru.mvista.com>
Signed-off-by: Kumar Gala <galak@kernel.crashing.org>
diff --git a/arch/powerpc/boot/dts/mpc8569mds.dts b/arch/powerpc/boot/dts/mpc8569mds.dts
index a680165..9e4ce99 100644
--- a/arch/powerpc/boot/dts/mpc8569mds.dts
+++ b/arch/powerpc/boot/dts/mpc8569mds.dts
@@ -501,6 +501,10 @@
reg = <0x6>;
device_type = "ethernet-phy";
};
+ tbi-phy@11 {
+ reg = <0x11>;
+ device_type = "tbi-phy";
+ };
};
mdio@3520 {
#address-cells = <1>;