|  | # PMBus chip drivers configuration | 
|  | # | 
|  |  | 
|  | menuconfig PMBUS | 
|  | tristate "PMBus support" | 
|  | depends on I2C && EXPERIMENTAL | 
|  | default n | 
|  | help | 
|  | Say yes here if you want to enable PMBus support. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called pmbus_core. | 
|  |  | 
|  | if PMBUS | 
|  |  | 
|  | config SENSORS_PMBUS | 
|  | tristate "Generic PMBus devices" | 
|  | default y | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for generic | 
|  | PMBus devices, including but not limited to ADP4000, BMR453, BMR454, | 
|  | MDT040, NCP4200, NCP4208, PDT003, PDT006, PDT012, UDT020, TPS40400, | 
|  | and TPS40422. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called pmbus. | 
|  |  | 
|  | config SENSORS_ADM1275 | 
|  | tristate "Analog Devices ADM1275 and compatibles" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Analog | 
|  | Devices ADM1075, ADM1275, and ADM1276 Hot-Swap Controller and Digital | 
|  | Power Monitors. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called adm1275. | 
|  |  | 
|  | config SENSORS_LM25066 | 
|  | tristate "National Semiconductor LM25066 and compatibles" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for National | 
|  | Semiconductor LM25066, LM5064, and LM5066. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called lm25066. | 
|  |  | 
|  | config SENSORS_LTC2978 | 
|  | tristate "Linear Technologies LTC2978 and LTC3880" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Linear | 
|  | Technology LTC2978 and LTC3880. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called ltc2978. | 
|  |  | 
|  | config SENSORS_MAX16064 | 
|  | tristate "Maxim MAX16064" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Maxim | 
|  | MAX16064. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called max16064. | 
|  |  | 
|  | config SENSORS_MAX34440 | 
|  | tristate "Maxim MAX34440 and compatibles" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Maxim | 
|  | MAX34440, MAX34441, and MAX34446. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called max34440. | 
|  |  | 
|  | config SENSORS_MAX8688 | 
|  | tristate "Maxim MAX8688" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Maxim | 
|  | MAX8688. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called max8688. | 
|  |  | 
|  | config SENSORS_UCD9000 | 
|  | tristate "TI UCD90120, UCD90124, UCD9090, UCD90910" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for TI | 
|  | UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health | 
|  | Controllers. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called ucd9000. | 
|  |  | 
|  | config SENSORS_UCD9200 | 
|  | tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for TI | 
|  | UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248 | 
|  | Digital PWM System Controllers. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called ucd9200. | 
|  |  | 
|  | config SENSORS_ZL6100 | 
|  | tristate "Intersil ZL6100 and compatibles" | 
|  | default n | 
|  | help | 
|  | If you say yes here you get hardware monitoring support for Intersil | 
|  | ZL2004, ZL2005, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, ZL6105, | 
|  | ZL9101M, and ZL9117M Digital DC/DC Controllers, as well as for | 
|  | Ericsson BMR450, BMR451, BMR462, BMR463, and BMR464. | 
|  |  | 
|  | This driver can also be built as a module. If so, the module will | 
|  | be called zl6100. | 
|  |  | 
|  | endif # PMBUS |