hwmon: exynos4: move thermal sensor driver to driver/thermal directory

This movement is needed because the hwmon entries and corresponding sysfs
interface is a duplicate of utilities already provided by
driver/thermal/thermal_sys.c.  The goal is to place it in thermal folder
and add necessary functions to use the in-kernel thermal interfaces.

Signed-off-by: Amit Daniel Kachhap <amit.kachhap@linaro.org>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
Cc: SangWook Ju <sw.ju@samsung.com>
Cc: Durgadoss <durgadoss.r@intel.com>
Cc: Len Brown <lenb@kernel.org>
Cc: Jean Delvare <khali@linux-fr.org>
Cc: Kyungmin Park <kmpark@infradead.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
diff --git a/Documentation/hwmon/exynos4_tmu b/Documentation/thermal/exynos_thermal
similarity index 70%
rename from Documentation/hwmon/exynos4_tmu
rename to Documentation/thermal/exynos_thermal
index c3c6b41..2b46f67 100644
--- a/Documentation/hwmon/exynos4_tmu
+++ b/Documentation/thermal/exynos_thermal
@@ -46,36 +46,7 @@
   The threshold and each trigger_level are set
   through the corresponding registers.
 
-When an interrupt occurs, this driver notify user space of
-one of four threshold levels for the interrupt
-through kobject_uevent_env and sysfs_notify functions.
+When an interrupt occurs, this driver notify kernel thermal framework
+with the function exynos4_report_trigger.
 Although an interrupt condition for level_0 can be set,
-it is not notified to user space through sysfs_notify function.
-
-Sysfs Interface
----------------
-name		name of the temperature sensor
-		RO
-
-temp1_input	temperature
-		RO
-
-temp1_max	temperature for level_1 interrupt
-		RO
-
-temp1_crit	temperature for level_2 interrupt
-		RO
-
-temp1_emergency	temperature for level_3 interrupt
-		RO
-
-temp1_max_alarm	alarm for level_1 interrupt
-		RO
-
-temp1_crit_alarm
-		alarm for level_2 interrupt
-		RO
-
-temp1_emergency_alarm
-		alarm for level_3 interrupt
-		RO
+it can be used to synchronize the cooling action.