| # | 
 | # Block device driver configuration | 
 | # | 
 |  | 
 | menuconfig MD | 
 | 	bool "Multiple devices driver support (RAID and LVM)" | 
 | 	depends on BLOCK | 
 | 	help | 
 | 	  Support multiple physical spindles through a single logical device. | 
 | 	  Required for RAID and logical volume management. | 
 |  | 
 | if MD | 
 |  | 
 | config BLK_DEV_MD | 
 | 	tristate "RAID support" | 
 | 	---help--- | 
 | 	  This driver lets you combine several hard disk partitions into one | 
 | 	  logical block device. This can be used to simply append one | 
 | 	  partition to another one or to combine several redundant hard disks | 
 | 	  into a RAID1/4/5 device so as to provide protection against hard | 
 | 	  disk failures. This is called "Software RAID" since the combining of | 
 | 	  the partitions is done by the kernel. "Hardware RAID" means that the | 
 | 	  combining is done by a dedicated controller; if you have such a | 
 | 	  controller, you do not need to say Y here. | 
 |  | 
 | 	  More information about Software RAID on Linux is contained in the | 
 | 	  Software RAID mini-HOWTO, available from | 
 | 	  <http://www.tldp.org/docs.html#howto>. There you will also learn | 
 | 	  where to get the supporting user space utilities raidtools. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config MD_AUTODETECT | 
 | 	bool "Autodetect RAID arrays during kernel boot" | 
 | 	depends on BLK_DEV_MD=y | 
 | 	default y | 
 | 	---help--- | 
 | 	  If you say Y here, then the kernel will try to autodetect raid | 
 | 	  arrays as part of its boot process.  | 
 |  | 
 | 	  If you don't use raid and say Y, this autodetection can cause  | 
 | 	  a several-second delay in the boot time due to various | 
 | 	  synchronisation steps that are part of this step. | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MD_LINEAR | 
 | 	tristate "Linear (append) mode" | 
 | 	depends on BLK_DEV_MD | 
 | 	---help--- | 
 | 	  If you say Y here, then your multiple devices driver will be able to | 
 | 	  use the so-called linear mode, i.e. it will combine the hard disk | 
 | 	  partitions by simply appending one to the other. | 
 |  | 
 | 	  To compile this as a module, choose M here: the module | 
 | 	  will be called linear. | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MD_RAID0 | 
 | 	tristate "RAID-0 (striping) mode" | 
 | 	depends on BLK_DEV_MD | 
 | 	---help--- | 
 | 	  If you say Y here, then your multiple devices driver will be able to | 
 | 	  use the so-called raid0 mode, i.e. it will combine the hard disk | 
 | 	  partitions into one logical device in such a fashion as to fill them | 
 | 	  up evenly, one chunk here and one chunk there. This will increase | 
 | 	  the throughput rate if the partitions reside on distinct disks. | 
 |  | 
 | 	  Information about Software RAID on Linux is contained in the | 
 | 	  Software-RAID mini-HOWTO, available from | 
 | 	  <http://www.tldp.org/docs.html#howto>. There you will also | 
 | 	  learn where to get the supporting user space utilities raidtools. | 
 |  | 
 | 	  To compile this as a module, choose M here: the module | 
 | 	  will be called raid0. | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MD_RAID1 | 
 | 	tristate "RAID-1 (mirroring) mode" | 
 | 	depends on BLK_DEV_MD | 
 | 	---help--- | 
 | 	  A RAID-1 set consists of several disk drives which are exact copies | 
 | 	  of each other.  In the event of a mirror failure, the RAID driver | 
 | 	  will continue to use the operational mirrors in the set, providing | 
 | 	  an error free MD (multiple device) to the higher levels of the | 
 | 	  kernel.  In a set with N drives, the available space is the capacity | 
 | 	  of a single drive, and the set protects against a failure of (N - 1) | 
 | 	  drives. | 
 |  | 
 | 	  Information about Software RAID on Linux is contained in the | 
 | 	  Software-RAID mini-HOWTO, available from | 
 | 	  <http://www.tldp.org/docs.html#howto>.  There you will also | 
 | 	  learn where to get the supporting user space utilities raidtools. | 
 |  | 
 | 	  If you want to use such a RAID-1 set, say Y.  To compile this code | 
 | 	  as a module, choose M here: the module will be called raid1. | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MD_RAID10 | 
 | 	tristate "RAID-10 (mirrored striping) mode" | 
 | 	depends on BLK_DEV_MD | 
 | 	---help--- | 
 | 	  RAID-10 provides a combination of striping (RAID-0) and | 
 | 	  mirroring (RAID-1) with easier configuration and more flexible | 
 | 	  layout. | 
 | 	  Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to | 
 | 	  be the same size (or at least, only as much as the smallest device | 
 | 	  will be used). | 
 | 	  RAID-10 provides a variety of layouts that provide different levels | 
 | 	  of redundancy and performance. | 
 |  | 
 | 	  RAID-10 requires mdadm-1.7.0 or later, available at: | 
 |  | 
 | 	  ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/ | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MD_RAID456 | 
 | 	tristate "RAID-4/RAID-5/RAID-6 mode" | 
 | 	depends on BLK_DEV_MD | 
 | 	select RAID6_PQ | 
 | 	select ASYNC_MEMCPY | 
 | 	select ASYNC_XOR | 
 | 	select ASYNC_PQ | 
 | 	select ASYNC_RAID6_RECOV | 
 | 	---help--- | 
 | 	  A RAID-5 set of N drives with a capacity of C MB per drive provides | 
 | 	  the capacity of C * (N - 1) MB, and protects against a failure | 
 | 	  of a single drive. For a given sector (row) number, (N - 1) drives | 
 | 	  contain data sectors, and one drive contains the parity protection. | 
 | 	  For a RAID-4 set, the parity blocks are present on a single drive, | 
 | 	  while a RAID-5 set distributes the parity across the drives in one | 
 | 	  of the available parity distribution methods. | 
 |  | 
 | 	  A RAID-6 set of N drives with a capacity of C MB per drive | 
 | 	  provides the capacity of C * (N - 2) MB, and protects | 
 | 	  against a failure of any two drives. For a given sector | 
 | 	  (row) number, (N - 2) drives contain data sectors, and two | 
 | 	  drives contains two independent redundancy syndromes.  Like | 
 | 	  RAID-5, RAID-6 distributes the syndromes across the drives | 
 | 	  in one of the available parity distribution methods. | 
 |  | 
 | 	  Information about Software RAID on Linux is contained in the | 
 | 	  Software-RAID mini-HOWTO, available from | 
 | 	  <http://www.tldp.org/docs.html#howto>. There you will also | 
 | 	  learn where to get the supporting user space utilities raidtools. | 
 |  | 
 | 	  If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To | 
 | 	  compile this code as a module, choose M here: the module | 
 | 	  will be called raid456. | 
 |  | 
 | 	  If unsure, say Y. | 
 |  | 
 | config MULTICORE_RAID456 | 
 | 	bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)" | 
 | 	depends on MD_RAID456 | 
 | 	depends on SMP | 
 | 	depends on EXPERIMENTAL | 
 | 	---help--- | 
 | 	  Enable the raid456 module to dispatch per-stripe raid operations to a | 
 | 	  thread pool. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config MD_MULTIPATH | 
 | 	tristate "Multipath I/O support" | 
 | 	depends on BLK_DEV_MD | 
 | 	help | 
 | 	  MD_MULTIPATH provides a simple multi-path personality for use | 
 | 	  the MD framework.  It is not under active development.  New | 
 | 	  projects should consider using DM_MULTIPATH which has more | 
 | 	  features and more testing. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config MD_FAULTY | 
 | 	tristate "Faulty test module for MD" | 
 | 	depends on BLK_DEV_MD | 
 | 	help | 
 | 	  The "faulty" module allows for a block device that occasionally returns | 
 | 	  read or write errors.  It is useful for testing. | 
 |  | 
 | 	  In unsure, say N. | 
 |  | 
 | config BLK_DEV_DM | 
 | 	tristate "Device mapper support" | 
 | 	---help--- | 
 | 	  Device-mapper is a low level volume manager.  It works by allowing | 
 | 	  people to specify mappings for ranges of logical sectors.  Various | 
 | 	  mapping types are available, in addition people may write their own | 
 | 	  modules containing custom mappings if they wish. | 
 |  | 
 | 	  Higher level volume managers such as LVM2 use this driver. | 
 |  | 
 | 	  To compile this as a module, choose M here: the module will be | 
 | 	  called dm-mod. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config DM_DEBUG | 
 | 	boolean "Device mapper debugging support" | 
 | 	depends on BLK_DEV_DM | 
 | 	---help--- | 
 | 	  Enable this for messages that may help debug device-mapper problems. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config DM_CRYPT | 
 | 	tristate "Crypt target support" | 
 | 	depends on BLK_DEV_DM | 
 | 	select CRYPTO | 
 | 	select CRYPTO_CBC | 
 | 	---help--- | 
 | 	  This device-mapper target allows you to create a device that | 
 | 	  transparently encrypts the data on it. You'll need to activate | 
 | 	  the ciphers you're going to use in the cryptoapi configuration. | 
 |  | 
 | 	  Information on how to use dm-crypt can be found on | 
 |  | 
 | 	  <http://www.saout.de/misc/dm-crypt/> | 
 |  | 
 | 	  To compile this code as a module, choose M here: the module will | 
 | 	  be called dm-crypt. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config DM_SNAPSHOT | 
 |        tristate "Snapshot target" | 
 |        depends on BLK_DEV_DM | 
 |        ---help--- | 
 |          Allow volume managers to take writable snapshots of a device. | 
 |  | 
 | config DM_MIRROR | 
 |        tristate "Mirror target" | 
 |        depends on BLK_DEV_DM | 
 |        ---help--- | 
 |          Allow volume managers to mirror logical volumes, also | 
 |          needed for live data migration tools such as 'pvmove'. | 
 |  | 
 | config DM_LOG_USERSPACE | 
 | 	tristate "Mirror userspace logging (EXPERIMENTAL)" | 
 | 	depends on DM_MIRROR && EXPERIMENTAL && NET | 
 | 	select CONNECTOR | 
 | 	---help--- | 
 | 	  The userspace logging module provides a mechanism for | 
 | 	  relaying the dm-dirty-log API to userspace.  Log designs | 
 | 	  which are more suited to userspace implementation (e.g. | 
 | 	  shared storage logs) or experimental logs can be implemented | 
 | 	  by leveraging this framework. | 
 |  | 
 | config DM_ZERO | 
 | 	tristate "Zero target" | 
 | 	depends on BLK_DEV_DM | 
 | 	---help--- | 
 | 	  A target that discards writes, and returns all zeroes for | 
 | 	  reads.  Useful in some recovery situations. | 
 |  | 
 | config DM_MULTIPATH | 
 | 	tristate "Multipath target" | 
 | 	depends on BLK_DEV_DM | 
 | 	# nasty syntax but means make DM_MULTIPATH independent | 
 | 	# of SCSI_DH if the latter isn't defined but if | 
 | 	# it is, DM_MULTIPATH must depend on it.  We get a build | 
 | 	# error if SCSI_DH=m and DM_MULTIPATH=y | 
 | 	depends on SCSI_DH || !SCSI_DH | 
 | 	---help--- | 
 | 	  Allow volume managers to support multipath hardware. | 
 |  | 
 | config DM_MULTIPATH_QL | 
 | 	tristate "I/O Path Selector based on the number of in-flight I/Os" | 
 | 	depends on DM_MULTIPATH | 
 | 	---help--- | 
 | 	  This path selector is a dynamic load balancer which selects | 
 | 	  the path with the least number of in-flight I/Os. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config DM_MULTIPATH_ST | 
 | 	tristate "I/O Path Selector based on the service time" | 
 | 	depends on DM_MULTIPATH | 
 | 	---help--- | 
 | 	  This path selector is a dynamic load balancer which selects | 
 | 	  the path expected to complete the incoming I/O in the shortest | 
 | 	  time. | 
 |  | 
 | 	  If unsure, say N. | 
 |  | 
 | config DM_DELAY | 
 | 	tristate "I/O delaying target (EXPERIMENTAL)" | 
 | 	depends on BLK_DEV_DM && EXPERIMENTAL | 
 | 	---help--- | 
 | 	A target that delays reads and/or writes and can send | 
 | 	them to different devices.  Useful for testing. | 
 |  | 
 | 	If unsure, say N. | 
 |  | 
 | config DM_UEVENT | 
 | 	bool "DM uevents (EXPERIMENTAL)" | 
 | 	depends on BLK_DEV_DM && EXPERIMENTAL | 
 | 	---help--- | 
 | 	Generate udev events for DM events. | 
 |  | 
 | endif # MD |