OMAPDSS: HDMI: Disable PLL properly in case of error at power_on

Small patch to disable the PLL appropriately before runtime_put in case
an error occurs while enabling the PHY.

Signed-off-by: Ricardo Neri <ricardo.neri@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
diff --git a/drivers/video/omap2/dss/hdmi.c b/drivers/video/omap2/dss/hdmi.c
index 060216f..a65dafa 100644
--- a/drivers/video/omap2/dss/hdmi.c
+++ b/drivers/video/omap2/dss/hdmi.c
@@ -501,7 +501,7 @@
 	r = hdmi.ip_data.ops->phy_enable(&hdmi.ip_data);
 	if (r) {
 		DSSDBG("Failed to start PHY\n");
-		goto err;
+		goto err_phy_enable;
 	}
 
 	hdmi.ip_data.ops->video_configure(&hdmi.ip_data);
@@ -537,6 +537,7 @@
 	hdmi.ip_data.ops->video_disable(&hdmi.ip_data);
 err_vid_enable:
 	hdmi.ip_data.ops->phy_disable(&hdmi.ip_data);
+err_phy_enable:
 	hdmi.ip_data.ops->pll_disable(&hdmi.ip_data);
 err:
 	hdmi_runtime_put();