hwmon: lis3: use block read to access data registers

Add optional blockread function to interface driver. If available
the chip driver uses it for data register access. For 12 bit device
it reads 6 bytes to get 3*16bit data. For 8 bit device it reads out
5 bytes since every second byte is dummy.
This optimizes bus usage and reduces number of operations and
interrupts needed for one data update.

Signed-off-by: Samu Onkalo <samu.p.onkalo@nokia.com>
Acked-by: Jonathan Cameron <jic23@cam.ac.uk>
Acked-by: Eric Piel <eric.piel@tremplin-utc.net>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
diff --git a/drivers/hwmon/lis3lv02d.h b/drivers/hwmon/lis3lv02d.h
index 77ebb15..fdbe899 100644
--- a/drivers/hwmon/lis3lv02d.h
+++ b/drivers/hwmon/lis3lv02d.h
@@ -244,6 +244,7 @@
 	int (*init) (struct lis3lv02d *lis3);
 	int (*write) (struct lis3lv02d *lis3, int reg, u8 val);
 	int (*read) (struct lis3lv02d *lis3, int reg, u8 *ret);
+	int (*blkread) (struct lis3lv02d *lis3, int reg, int len, u8 *ret);
 	int (*reg_ctrl) (struct lis3lv02d *lis3, bool state);
 
 	int                     *odrs;     /* Supported output data rates */