clocksource: ARM sp804: allow clocksource name to be specified

This allows platforms to specify the clocksource name upon
registration, which is necessary should they wish to register more
than one sp804 clocksource.

Acked-by: Catalin Marinas <catalin.marinas@arm.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
diff --git a/arch/arm/common/timer-sp.c b/arch/arm/common/timer-sp.c
index 445b05e..f6b9011 100644
--- a/arch/arm/common/timer-sp.c
+++ b/arch/arm/common/timer-sp.c
@@ -32,7 +32,7 @@
 #define TIMER_FREQ_KHZ	(1000)
 #define TIMER_RELOAD	(TIMER_FREQ_KHZ * 1000 / HZ)
 
-void __init sp804_clocksource_init(void __iomem *base)
+void __init sp804_clocksource_init(void __iomem *base, const char *name)
 {
 	/* setup timer 0 as free-running clocksource */
 	writel(0, base + TIMER_CTRL);
@@ -41,7 +41,7 @@
 	writel(TIMER_CTRL_32BIT | TIMER_CTRL_ENABLE | TIMER_CTRL_PERIODIC,
 		base + TIMER_CTRL);
 
-	clocksource_mmio_init(base + TIMER_VALUE, "timer3",
+	clocksource_mmio_init(base + TIMER_VALUE, name,
 		TIMER_FREQ_KHZ * 1000, 200, 32, clocksource_mmio_readl_down);
 }