Philip, Avinash333b08e2012-11-27 14:18:09 +05301TI SOC ECAP based APWM controller
2
3Required properties:
Philip Avinash5df1b8f2013-03-25 12:34:52 +05304- compatible: Must be "ti,<soc>-ecap".
5 for am33xx - compatible = "ti,am33xx-ecap";
6 for da850 - compatible = "ti,da850-ecap", "ti,am33xx-ecap";
Philip, Avinash333b08e2012-11-27 14:18:09 +05307- #pwm-cells: Should be 3. Number of cells being used to specify PWM property.
8 First cell specifies the per-chip index of the PWM to use, the second
9 cell is the period in nanoseconds and bit 0 in the third cell is used to
10 encode the polarity of PWM output. Set bit 0 of the third in PWM specifier
11 to 1 for inverse polarity & set to 0 for normal polarity.
12- reg: physical base address and size of the registers map.
13
14Optional properties:
15- ti,hwmods: Name of the hwmod associated to the ECAP:
16 "ecap<x>", <x> being the 0-based instance number from the HW spec
17
18Example:
19
Philip Avinash5df1b8f2013-03-25 12:34:52 +053020ecap0: ecap@0 { /* ECAP on am33xx */
Philip, Avinash333b08e2012-11-27 14:18:09 +053021 compatible = "ti,am33xx-ecap";
22 #pwm-cells = <3>;
23 reg = <0x48300100 0x80>;
24 ti,hwmods = "ecap0";
25};
Philip Avinash5df1b8f2013-03-25 12:34:52 +053026
27ecap0: ecap@0 { /* ECAP on da850 */
28 compatible = "ti,da850-ecap", "ti,am33xx-ecap";
29 #pwm-cells = <3>;
30 reg = <0x306000 0x80>;