| Guenter Roeck | e428d8d | 2011-04-18 09:55:59 -0700 | [diff] [blame] | 1 | Kernel driver max34440 | 
 | 2 | ====================== | 
 | 3 |  | 
 | 4 | Supported chips: | 
 | 5 |   * Maxim MAX34440 | 
 | 6 |     Prefixes: 'max34440' | 
 | 7 |     Addresses scanned: - | 
 | 8 |     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf | 
 | 9 |   * Maxim MAX34441 | 
 | 10 |     PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller | 
 | 11 |     Prefixes: 'max34441' | 
 | 12 |     Addresses scanned: - | 
 | 13 |     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf | 
 | 14 |  | 
 | 15 | Author: Guenter Roeck <guenter.roeck@ericsson.com> | 
 | 16 |  | 
 | 17 |  | 
 | 18 | Description | 
 | 19 | ----------- | 
 | 20 |  | 
 | 21 | This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel | 
 | 22 | Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager | 
 | 23 | and Intelligent Fan Controller. | 
 | 24 |  | 
 | 25 | The driver is a client driver to the core PMBus driver. Please see | 
 | 26 | Documentation/hwmon/pmbus for details on PMBus client drivers. | 
 | 27 |  | 
 | 28 |  | 
 | 29 | Usage Notes | 
 | 30 | ----------- | 
 | 31 |  | 
 | 32 | This driver does not auto-detect devices. You will have to instantiate the | 
 | 33 | devices explicitly. Please see Documentation/i2c/instantiating-devices for | 
 | 34 | details. | 
 | 35 |  | 
 | 36 |  | 
 | 37 | Platform data support | 
 | 38 | --------------------- | 
 | 39 |  | 
 | 40 | The driver supports standard PMBus driver platform data. | 
 | 41 |  | 
 | 42 |  | 
 | 43 | Sysfs entries | 
 | 44 | ------------- | 
 | 45 |  | 
 | 46 | The following attributes are supported. Limits are read-write; all other | 
 | 47 | attributes are read-only. | 
 | 48 |  | 
 | 49 | in[1-6]_label		"vout[1-6]". | 
 | 50 | in[1-6]_input		Measured voltage. From READ_VOUT register. | 
 | 51 | in[1-6]_min		Minumum Voltage. From VOUT_UV_WARN_LIMIT register. | 
 | 52 | in[1-6]_max		Maximum voltage. From VOUT_OV_WARN_LIMIT register. | 
 | 53 | in[1-6]_lcrit		Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register. | 
 | 54 | in[1-6]_crit		Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. | 
 | 55 | in[1-6]_min_alarm	Voltage low alarm. From VOLTAGE_UV_WARNING status. | 
 | 56 | in[1-6]_max_alarm	Voltage high alarm. From VOLTAGE_OV_WARNING status. | 
 | 57 | in[1-6]_lcrit_alarm	Voltage critical low alarm. From VOLTAGE_UV_FAULT status. | 
 | 58 | in[1-6]_crit_alarm	Voltage critical high alarm. From VOLTAGE_OV_FAULT status. | 
| Guenter Roeck | 98591db | 2011-07-09 13:17:43 -0700 | [diff] [blame] | 59 | in[1-6]_highest		Historical maximum voltage. | 
 | 60 | in[1-6]_reset_history	Write any value to reset history. | 
| Guenter Roeck | e428d8d | 2011-04-18 09:55:59 -0700 | [diff] [blame] | 61 |  | 
 | 62 | curr[1-6]_label		"iout[1-6]". | 
 | 63 | curr[1-6]_input		Measured current. From READ_IOUT register. | 
 | 64 | curr[1-6]_max		Maximum current. From IOUT_OC_WARN_LIMIT register. | 
 | 65 | curr[1-6]_crit		Critical maximum current. From IOUT_OC_FAULT_LIMIT register. | 
 | 66 | curr[1-6]_max_alarm	Current high alarm. From IOUT_OC_WARNING status. | 
 | 67 | curr[1-6]_crit_alarm	Current critical high alarm. From IOUT_OC_FAULT status. | 
| Guenter Roeck | 98591db | 2011-07-09 13:17:43 -0700 | [diff] [blame] | 68 | curr[1-6]_highest	Historical maximum current. | 
 | 69 | curr[1-6]_reset_history	Write any value to reset history. | 
| Guenter Roeck | e428d8d | 2011-04-18 09:55:59 -0700 | [diff] [blame] | 70 |  | 
 | 71 | 			in6 and curr6 attributes only exist for MAX34440. | 
 | 72 |  | 
 | 73 | temp[1-8]_input		Measured temperatures. From READ_TEMPERATURE_1 register. | 
 | 74 | 			temp1 is the chip's internal temperature. temp2..temp5 | 
 | 75 | 			are remote I2C temperature sensors. For MAX34441, temp6 | 
 | 76 | 			is a remote thermal-diode sensor. For MAX34440, temp6..8 | 
 | 77 | 			are remote I2C temperature sensors. | 
 | 78 | temp[1-8]_max		Maximum temperature. From OT_WARN_LIMIT register. | 
 | 79 | temp[1-8]_crit		Critical high temperature. From OT_FAULT_LIMIT register. | 
 | 80 | temp[1-8]_max_alarm	Temperature high alarm. | 
 | 81 | temp[1-8]_crit_alarm	Temperature critical high alarm. | 
| Guenter Roeck | 98591db | 2011-07-09 13:17:43 -0700 | [diff] [blame] | 82 | temp[1-8]_highest	Historical maximum temperature. | 
 | 83 | temp[1-8]_reset_history	Write any value to reset history. | 
| Guenter Roeck | e428d8d | 2011-04-18 09:55:59 -0700 | [diff] [blame] | 84 |  | 
 | 85 | 			temp7 and temp8 attributes only exist for MAX34440. |