| Hartmut Knaack | 983b97b | 2012-08-12 18:15:49 +0200 | [diff] [blame] | 1 | Kernel driver adt7410 | 
 | 2 | ===================== | 
 | 3 |  | 
 | 4 | Supported chips: | 
 | 5 |   * Analog Devices ADT7410 | 
 | 6 |     Prefix: 'adt7410' | 
 | 7 |     Addresses scanned: I2C 0x48 - 0x4B | 
 | 8 |     Datasheet: Publicly available at the Analog Devices website | 
 | 9 |                http://www.analog.com/static/imported-files/data_sheets/ADT7410.pdf | 
 | 10 |  | 
 | 11 | Author: Hartmut Knaack <knaack.h@gmx.de> | 
 | 12 |  | 
 | 13 | Description | 
 | 14 | ----------- | 
 | 15 |  | 
 | 16 | The ADT7410 is a temperature sensor with rated temperature range of -55°C to | 
 | 17 | +150°C. It has a high accuracy of +/-0.5°C and can be operated at a resolution | 
 | 18 | of 13 bits (0.0625°C) or 16 bits (0.0078°C). The sensor provides an INT pin to | 
 | 19 | indicate that a minimum or maximum temperature set point has been exceeded, as | 
 | 20 | well as a critical temperature (CT) pin to indicate that the critical | 
 | 21 | temperature set point has been exceeded. Both pins can be set up with a common | 
 | 22 | hysteresis of 0°C - 15°C and a fault queue, ranging from 1 to 4 events. Both | 
 | 23 | pins can individually set to be active-low or active-high, while the whole | 
 | 24 | device can either run in comparator mode or interrupt mode. The ADT7410 | 
 | 25 | supports continous temperature sampling, as well as sampling one temperature | 
 | 26 | value per second or even justget one sample on demand for power saving. | 
 | 27 | Besides, it can completely power down its ADC, if power management is | 
 | 28 | required. | 
 | 29 |  | 
 | 30 | Configuration Notes | 
 | 31 | ------------------- | 
 | 32 |  | 
 | 33 | Since the device uses one hysteresis value, which is an offset to minimum, | 
 | 34 | maximum and critical temperature, it can only be set for temp#_max_hyst. | 
 | 35 | However, temp#_min_hyst and temp#_crit_hyst show their corresponding | 
 | 36 | hysteresis. | 
 | 37 | The device is set to 16 bit resolution and comparator mode. | 
 | 38 |  | 
 | 39 | sysfs-Interface | 
 | 40 | --------------- | 
 | 41 |  | 
 | 42 | temp#_input		- temperature input | 
 | 43 | temp#_min		- temperature minimum setpoint | 
 | 44 | temp#_max		- temperature maximum setpoint | 
 | 45 | temp#_crit		- critical temperature setpoint | 
 | 46 | temp#_min_hyst		- hysteresis for temperature minimum (read-only) | 
 | 47 | temp#_max_hyst		- hysteresis for temperature maximum (read/write) | 
 | 48 | temp#_crit_hyst		- hysteresis for critical temperature (read-only) | 
 | 49 | temp#_min_alarm		- temperature minimum alarm flag | 
 | 50 | temp#_max_alarm		- temperature maximum alarm flag | 
 | 51 | temp#_crit_alarm	- critical temperature alarm flag |